SK6021 series air pressure controls is used to sense tiny pressure change and widely used to control the flow of aerator, to monitor fan and air conditioner It is also suitable for over heating protection and frost protection in industrial cooling system. Due to its oustanding design,the set point can be adjusted visually.
Application
SK6021 pressure switch can be used to sense
(Differential) pressure and flow of air in ducts and pipes
.Typical applications include:
-Filter obstructive alarm.
-Air proving in ventilation ducts.
-Maximum air flow controller for variable air volume systems.
-Burner air control
Specifications
Â
Product name | Waterproof Switch Air Differential Pressure Switch |
Media | Air,non-combustible and non-aggressive gas |
Max Operating Pressure | 10 kPa |
Mounting Position | Diaphragm in any vertical plane |
Degree of protection | IP54 (with cover) |
Operating Temperature | -40° C to 85° C |
Contact Arrangement | SPDT |
Electrical Rating |
Resistance: Initial: < 50 milliohms; Current:1.5A resistive(0.4A inductive) @ 250V |
Electric Connection | 6.3 x 0.8 blade 46244 or screw terminals |
Material |
Housing: ABS Duct connectors: ABS Membrane: Silicone Cable sleeve: PVC |
Weight | 0.15kg(0.35kg with flexible pipe) |
Connection | 6.0mm Dia. for tube connection |
Approval | UL, CE, RoHS |
Wiring (Screw terminal):
Â
Â
SK6021 series air pressure controls is used to sense tiny pressure change and widely used to control the flow of aerator, to monitor fan and air conditioner It is also suitable for over heating protection and frost protection in industrial cooling system. Due to its oustanding design,the set point can be adjusted visually.
Application
SK6021 pressure switch can be used to sense
(Differential) pressure and flow of air in ducts and pipes
.Typical applications include:
-Filter obstructive alarm.
-Air proving in ventilation ducts.
-Maximum air flow controller for variable air volume systems.
-Burner air control
Specifications
Â
Product name | Waterproof Switch Air Differential Pressure Switch |
Media | Air,non-combustible and non-aggressive gas |
Max Operating Pressure | 10 kPa |
Mounting Position | Diaphragm in any vertical plane |
Degree of protection | IP54 (with cover) |
Operating Temperature | -40° C to 85° C |
Contact Arrangement | SPDT |
Electrical Rating |
Resistance: Initial: < 50 milliohms; Current:1.5A resistive(0.4A inductive) @ 250V |
Electric Connection | 6.3 x 0.8 blade 46244 or screw terminals |
Material |
Housing: ABS Duct connectors: ABS Membrane: Silicone Cable sleeve: PVC |
Weight | 0.15kg(0.35kg with flexible pipe) |
Connection | 6.0mm Dia. for tube connection |
Approval | UL, CE, RoHS |
Wiring (Screw terminal):
Â
Â
R40/BR40 Bulb,R40 / BR40 LED Light,Energy Star R40 Bulb