- Application: Construction, Underground, Power Station
- Current: AC Cable
- Sheath Material: PVC
- Wire Core Material: Bare Copper Wire
- Model: Yjv32
- Product Name: XLPE Insulated,Armoured,PVC Sheathed Cable
- Transport Package: Drum, Reel or According to Your Request
- Origin: Zhengzhou, Henan, China
- Voltage: Low and Medium Voltage Cable
- Insulation Material: XLPE
- Material Shape: Round Wire
- Certification: ISO, CCC, CE
- Brand: Yifang
- Trademark: YIFANG
- Specification: IEC, BS, DIN, ASTM, NFC, JIS etc
- HS Code: 8544492100
1.Brief of XLPE Insulated Power Cable
Â
XLPE insulated power cable has a number of advantages over paper insulated and PVC insulated
cable. XLPE cable has high electric strength, mechanical strength, high-ageing resistance, environmental
stress resisting anti-chemical corrosion, and it is simple construction, using convenient and higher operating of
long term temperature. It can be laid with no drop restriction.
2.Scope of XLPE Cable
Â
Â
3.Main technical Characteristics of Cable
4. Service conditions and Parameters of Cable
Â
The cable is applied to fixed installation for rated voltage 0.6/1KV of power transportation and distribution line.
Max. Rated Temperature of conductor: Nominal Operating 90 .
Short circit: (Max.for 5 sec.) 250
Temperature of laying, in air 25
Underground 15
For laying, single core, triangle laying for three cables.
Depth of laying in direct:100cm
Coefficient of thermal resistivity of soil 100 .cm/w
The cable can be laid without drop restriction, and the environment temperature shall not be lower than 0 .
Single core, steel tape armoured cable should be only aplied to direct-circuit line.
For nominal insulation thickness, size of armour, over-diameter, weight and current rating of retardantflame
cable of class A,B,C, you should refer to the value of general cable.
Â
Nominal Cross Section mm 2 | Main cores | 2.5 | 4 | 6 | 10 | 16 | 25 | 35 | 50 |
Neutral cores | 1.5 | 2.5 | 4 | 6 | 10 | 16 | 16 | 25 | |
Nominal Cross Section mm 2 | Main cores | 70 | 95 | 120 | 150 | 185 | 240 | 300 | 400 |
Neutral cores | 35 | 50 | 70 | 70 | 95 | 120 | 150 | 185 |
Nominal Cross Section mm 2 | 1.5 | 2.5 | 4 | 6 | 10 | 16 | 25 |
Cu core Ohm/km | 12.1 | 7.41 | 4.61 | 3.08 | 1.83 | 1.15 | 0.727 |
Al core Ohm/km | 18.1 | 12.1 | 7.41 | 4.61 | 3.08 | 1.91 | 1.2 |
Nominal Cross Section mm 2 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
Cu core Ohm/km | 0.524 | 0.387 | 0.268 | 0.193 | 0.153 | 0.124 | 0.0991 |
Al core Ohm/km | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 |
Nominal Cross Section mm 2 | 240 | 300 | 400 | 500 | 630 | 800 | 1000 |
Cu core Ohm/km | 0.0754 | 0.06 | 0.047 | 0.0366 | 0.0283 | 0.0221 | 0.0176 |
Al core Ohm/km | 0.125 | 0.1 | 0.0778 | 0.0605 | 0.0469 | 0.0367 | 0.0291 |
Fiber ST To ST Adapter is also known as ST fiber optic mating sleeves. Fiber optic ST adapters are used to provide a cable to cable or cable to equipment fiber optic connection. Foclink supplies a wide range of mating single mode and multimode ST Adapter, zirconia sleeve and bronze sleeve, simplex and duplex ST coupler. Hybrid fiber optic ST adapters,such as female to male & male to male fiber adapters, are widely applied in optical communication system, cable television network, LAN. We offer an extensive line of fiber optic adapters that offer superior low loss performance with very high repeatability.