Fire Alarm Cable
1)Structure: 2*1.0mm sq. With shielded
Conductor: 1.0/1.5/2.0/2.5mm sq.
Core: Can 2 cores, 4cores, 6cores.
Conductor: 2*2.5 mm2 Cu.
Shield: Aluminum foil with drain Insulation:
PVC Jacket: Low Smoke Zero Halogen material, LSZH outer sheath. These cables are produced to be able to work between 30 and 180 minutes in fire situation, This cable is available from 0.5 to 2.5 sqmm and from 2 to 5 cores.
A> Conductor: BC
B> Cable core: 2C
C> Insulation: PVC
D> rip cord: Yes
E> Shield: With Al/foil
F> Drain wire: Yes
G> Jacket:
Water resistant and sunlight resistance PVC jacket
2)Standard packing:
100m/rolll, 100m/box; 200m/roll, 305m/wooden drum
Construction: 18 AWG solid bare copper, PVC insulation, color coded, cabled, aluminum / polyester foil tape plus tinned stranded copper drain(22 AWG), yellow PVC jacket, surface printed.
This 2 conductor #18 stranded wire has an insulation thickness of 9 (PVC) mils with the jacket thickness of 15 mils (PVC). The outside diameter is. 162 inches and the net weight of 1000 feet of cable is 22 lbs. The capacitance is 53 picofarads per inch. The colors of the insulation on the 2 solid copper conductors are black and red.
Decription  |
Conductor Spec. Â |
Insulation | Jacket | Insulatioon | ||
Nom.Thick (mm) |
Nom.Diam. (mm) |
Nom.Thick (mm) |
Nom.Diam. (mm) |
|||
BCAL/Pet , Polyester | 2*1.0 | 0.6 | 2..4 | 1.0 | 6.8 | Box Coil Drum Paper reel Plastic reel Wooden reel |
2*1.5 | 0.7 | 2.8 | 0.8 | 7.2 | ||
2*2.5 | 0.8 | 3.4 | 1.0 | 9 | ||
4*0.5 | 0.4 | 1.6 | 1.2 | 6.2 | ||
4*1.0 | 0.6 | 2..4 | 0.8 | 7.4 | ||
4*1.5 | 0.7 | 2.8 | 0.8 | 8.3 | ||
4*2.5 | 0.8 | 3.4 | 1.1 | 10.3 Â |






 High Performance 2-8 Core Copper Red Fire Alarm Cable
Fire Alarm Cable
1)Structure: 2*1.0mm sq. With shielded
Conductor: 1.0/1.5/2.0/2.5mm sq.
Core: Can 2 cores, 4cores, 6cores.
Conductor: 2*2.5 mm2 Cu.
Shield: Aluminum foil with drain Insulation:
PVC Jacket: Low Smoke Zero Halogen material, LSZH outer sheath. These cables are produced to be able to work between 30 and 180 minutes in fire situation, This cable is available from 0.5 to 2.5 sqmm and from 2 to 5 cores.
A> Conductor: BC
B> Cable core: 2C
C> Insulation: PVC
D> rip cord: Yes
E> Shield: With Al/foil
F> Drain wire: Yes
G> Jacket:
Water resistant and sunlight resistance PVC jacket
2)Standard packing:
100m/rolll, 100m/box; 200m/roll, 305m/wooden drum
Construction: 18 AWG solid bare copper, PVC insulation, color coded, cabled, aluminum / polyester foil tape plus tinned stranded copper drain(22 AWG), yellow PVC jacket, surface printed.
This 2 conductor #18 stranded wire has an insulation thickness of 9 (PVC) mils with the jacket thickness of 15 mils (PVC). The outside diameter is. 162 inches and the net weight of 1000 feet of cable is 22 lbs. The capacitance is 53 picofarads per inch. The colors of the insulation on the 2 solid copper conductors are black and red.
Decription  |
Conductor Spec. Â |
Insulation | Jacket | Insulatioon | ||
Nom.Thick (mm) |
Nom.Diam. (mm) |
Nom.Thick (mm) |
Nom.Diam. (mm) |
|||
BCAL/Pet , Polyester | 2*1.0 | 0.6 | 2..4 | 1.0 | 6.8 | Box Coil Drum Paper reel Plastic reel Wooden reel |
2*1.5 | 0.7 | 2.8 | 0.8 | 7.2 | ||
2*2.5 | 0.8 | 3.4 | 1.0 | 9 | ||
4*0.5 | 0.4 | 1.6 | 1.2 | 6.2 | ||
4*1.0 | 0.6 | 2..4 | 0.8 | 7.4 | ||
4*1.5 | 0.7 | 2.8 | 0.8 | 8.3 | ||
4*2.5 | 0.8 | 3.4 | 1.1 | 10.3 Â |






Â
Ceramic fuses are made by porcelain and some metal materials. When a circuit breaks down or is abnormal, the current increases with the current and the increased current may damage some important components in the circuit, and it may also burn the circuit and even cause a fire. Fuse is small safety part in an electrical device or piece of machinery that causes it to stop working if the electric current is too high, and so prevents fires or other dangers. Fuse in the abnormal current increases to a certain height and heat, its own fuse to cut off the current, to protect the safe operation of the circuit fuse protection power equipment with current overheating damage, avoid electronic equipment serious damage caused by internal fault. If correctly placed in the circuit fuse, the fuse will be abnormal current increases to a certain height and heat, its own fuse to cut off the current, so as to protect the safe operation of the circuit.