Norden Communication is proud to announce its participation as the Diamond Partner at the upcoming Broadband India Summit 2024, scheduled for 27th September 2024 at The LaLiT, New Delhi. This prestigious event will bring together leaders in the broadband and communication industry to discuss innovations, trends, and the future of high-speed connectivity.
As a global leader in communication solutions, Norden will be showcasing its state-of-the-art technologies designed to meet the demands of tomorrow’s broadband needs. Our team of experts will be on hand to provide insights and product demonstrations, highlighting how Norden is shaping the future of broadband across various industries.
Event Highlights:
Live product demonstrations of Norden’s cutting-edge broadband solutions
Expert talks and industry insights
Networking opportunities with industry leaders
Join us at the Broadband India Summit 2024 and experience how Norden is revolutionising broadband technology.
Learn More about the Broadband India Summit 2024 Click here
Dropout Fuse Cutout and load drop fuse cutout are outdoor used high-voltage protective devices. They are connected with the main lines of the distribution transformer or the distribution wires to protect the transformer or wires from short circuit and overload, and on/off loading current. Dropout fuse cutout consists of insulating bracket and fuse tube. The static contacts are fixed on the two ends of bracket, while the moving contacts are fixed on the two ends of fuse tube. Fuse tube is composed of inner extinction tube and the outer epoxy glass tube. The load drop fuse cutout is added with elastic supporting contacts and arcing shield for switching on-off loading current. In normal operation, the fuse tube will form an enclosure via its tightened fuse link. The fuse will be melt off quickly and form an arc if there is any fault, the extinction tube is heated by the arc, exploding much gas to give high pressure into the tube and blow along with the tube, so the arc is quickly elongated and extinguished. When the fuse is cut off, moving contacts at the bottom turn down without tension; the locking frame will release the fuse, so the fuse drops to form obvious break. When it needs to put load on, start the contact with insulating cod, then the static and moving contacts are still keeping in touch, keep pulling the contacts till the supporting contacts apart. Then there is the arc among the supporting contacts, which is prolonged in the narrow space of arcing shield.At the same time, the arc extinguishing cover generates gas, and the arc is extinguished when the current exceeds zero.
Porcelain Fuse Cutout,Drop Fuse Cutout,Fuse Link Cut Out,Cutout Fuse Holder