China National Nuclear Reactor Demonstration Project No. 1 and Unit 2 Clock System (EF05) Project Tender Notice
The owner of the NPP demonstration project is the State Nuclear Demonstration Power Plant Co., Ltd. The company was established in December 2009 and is controlled by the State Nuclear Power Technology Corporation and China Huaneng Group Corporation.
In view of the fact that China National Nuclear Demonstration Power Plant Co., Ltd. has signed the EPC general contracting contract with the National Nuclear Power Unit for the demonstration of nuclear power reactor demonstration unit No. 1 and No. 2, the procurement of equipment for the NPP PWR No. 1 and No. 2 units will be implemented by the State Nuclear Power. Engineering Co., Ltd. bears.
In view of the fact that China National Nuclear Engineering Co., Ltd. has signed subcontracts with Shandong Ludian International Trading Co., Ltd. on the China Nuclear Power PWR demonstration unit No. 1 and No. 2 conventional islands and BOP parts, SPC demonstration No. 1 and No. 2 unit conventional islands The procurement of equipment for its BOP part is undertaken by Shandong Ludian International Trade Co., Ltd.
In view of the mutual agreement between Guonuo Engineering Co., Ltd. and Shandong Ludian International Trading Co., Ltd.: Joint purchase of the entire plant clock system (EF05) of the National Nuclear Power PWR Model No. 1 and Unit No. 2 and the approval of Guonuo Engineering Co., Ltd. After the calibration, CNNC Engineering Co., Ltd. and Shandong Ludian International Trading Co., Ltd. each signed a procurement contract with the successful bidder according to the scope of the tendered items, and each was responsible for the implementation of the contract.
China National Nuclear Engineering Co., Ltd., as the bidder of the procurement project for the No. 1 and No. 2 Unit Clock System (EF05) of the State Nuclear Power Demonstration Project, has already met the tendering conditions.
China National Nuclear Engineering Co., Ltd. as a bidder will follow the principle of “openness, fairness, fairness, honesty, and excellence†to conduct the bidding.
1.0 Project Profile (1) Bidding Project Name Nuclear power PWR demonstration project No. 1 and No. 2 clock system (EF05) procurement project.
(2) Project Overview
China National Nuclear Power PWR Demonstration Unit 1, Unit 2 The National Nuclear Power Water Demonstration Project No. 1 and No. 2 units are located in Ningjin Town, Rongcheng City, Weihai, Shandong Province, and two CAP1400 pressurized water reactor nuclear power units are planned to be constructed. Unit 1 is scheduled to water the first tank concrete (FCD) on September 30, 2016. The FCD between Unit 2 and Unit 1 is 12 months apart.
2.0 Bidding Scope Device Name: EF05 Clock System
Nuclear Island (Procurement Party: State Nuclear Engineering Co., Ltd.)
Quantity: 2 sets (1 set/unit)
key parameter:
l Master clock power consumption: ≤200W; master clock travel accuracy ≤10-8s
l The master clock synchronization signal includes at least: second pulse, minute pulse, time pulse, IRIG-B (DC), IRIG-B (AC), serial port pairing, and NTP network pair time.
l The master clock physical interface includes at least: RS-485/422, RS-232, TTL, air contact, AC modulation, optical fiber, and Ethernet.
l Sub-clock power consumption ≤ 30W; sub-clock travel time accuracy ≤ 1 second/month
l 60 years cumulative dose: 10Gy-gamma
Conventional Island and BOP (Procurement: Shandong Ludian International Trading Co., Ltd.)
Quantity: 2 sets (1 set/unit)
key parameter:
l Master clock power consumption: ≤200W; master clock travel accuracy ≤10-8s
l The master clock and secondary master clock synchronization signals at least include: second pulse, minute pulse, time pulse, IRIG-B (DC), IRIG-B (AC), serial port pairing, and NTP network pair time.
l The physical interface of the master clock and secondary master clock includes at least: RS-485/422, RS-232, TTL, null contact, AC modulation, optical fiber, and Ethernet.
l Secondary master clock power consumption 50W; secondary master clock travel time accuracy ≤10-8s
l Sub-clock power consumption ≤ 30W; sub-clock travel time accuracy ≤ 1 second/month
l 60 years cumulative dose: 10Gy-gamma
Note:
1. The bidder must respond to the supply scope of the nuclear island section, conventional island and BOP section at the same time, otherwise the bid will be rejected.
2. The specific technical specifications, quantities, etc. shall be subject to the Chapter VI "Technical Requirements and Scope of Supply" of this document. The tender documents are not clearly shown in the technical drawings.
3.0 Qualified bidders shall be domestic manufacturers that meet the qualification requirements. Domestic production companies should have the financial strength, technical ability and production experience to successfully fulfill the contract. Specific conditions should meet the following conditions:
(1) Bidders shall be companies registered in the territory of the People's Republic of China (excluding Hong Kong, Macao, and Taiwan) in accordance with the "Company Law of the People's Republic of China" and have independent legal personality and capable of providing products and services for the project.
(2) It shall have a valid business license, qualification certificate, and production license and the scope and scope shall cover the tendered goods. And the above certificate should be consistent with the name of the bidder.
(3) The bidder’s registered capital must be RMB 20,000 and above.
(4) Bidders must be VAT general taxpayers. Bidders are required to submit business licenses, tax registration certificates (including national tax and local tax) and copies of general taxpayer qualification certification (both must be affixed with official seals and provide originals for future reference), as well as legal representative certificates and original legal representative power of attorney .
(5) Bidders may not be placed in a situation of being ordered to suspend business, property being taken over or frozen. Provides financial audit reports for the past three years.
(6) No major project quality problems can occur in the project completed by the bidder, and the bidder may not commit serious breach of contract.
(7) Do not accept quotes other than RMB.
(8) The Commonwealth does not accept bids in this tender.
(9) This tender does not accept bids from agents/dealers.
(10) Two or more companies (companies) whose legal representative is the same person; parent company, wholly-owned subsidiary and its holding company; and two companies that have direct or indirect holding or management relationships with each other. More than two companies (companies). With one of the aforementioned circumstances, only one of the companies (companies) can apply for a bid. In the event of simultaneous registration, the multiple applicants will also be refused to participate in the bidding for this project.
(11) The bidder must hold an ISO9001 quality management system certification and be within the validity period.
4.0 Acquisition of Bidding Documents (1) Time for tender documents for sale by tenderers: From September 9 to September 22, 2016 (excluding national holidays and public holidays) From 9:00 to 11:00 and from 14:00 to 17:00 ( Beijing time).
Contact: Chen Yumin
Cell phone
phone
mailbox:
In order to ensure that you can bid smoothly, please consult the bidding agency or the tenderer for detailed requirements for bidding before bidding or purchasing the bidding documents. The specific requirements and project conditions shall be interpreted by the bidding agency or the tenderer.
A single-phase VFD, also known as a variable frequency drive, is a specialized electronic device used for precise control and regulation of single-phase motors. Unlike three-phase motors that are commonly used in industrial applications, single-phase motors are predominantly found in residential and small-scale applications.
The primary function of a single-phase VFD is to control the frequency and voltage supplied to the single-phase motor, thereby enabling accurate regulation of motor speed. By adjusting the frequency and voltage output, the VFD allows for smooth and precise control over the motor's rotational speed. This feature is particularly useful in applications where speed control is required, such as in residential HVAC systems, small-scale machinery, and household appliances.
Energy efficiency is a significant advantage offered by single-phase VFDs. By adjusting the motor speed to match the load requirements, the VFD reduces energy wastage and improves overall energy efficiency. When the motor operates at a lower speed during periods of low demand, energy consumption is significantly reduced, resulting in energy savings and lower operating costs.
Motor protection is another important aspect addressed by single-phase VFDs. They incorporate various protective features, including overload protection, short circuit detection, and thermal protection, which help safeguard the motor against damage due to excessive current, voltage fluctuations, or overheating. This ensures reliable motor operation, prolongs the motor's lifespan, and reduces the risk of unexpected failures.
Harmonic filtering is also a critical consideration in single-phase VFD applications. When single-phase VFDs operate, they can introduce harmonics into the power supply, which may cause issues such as voltage distortions and interference with other electrical equipment. To mitigate these problems, single-phase VFDs often incorporate harmonic filtering techniques to suppress harmonics and ensure a clean and stable power supply, maintaining power quality and preventing damage to connected equipment.
Control algorithms play a significant role in single-phase VFD operation. These algorithms allow for precise control and adjustment of motor speed, ensuring smooth acceleration, deceleration, and accurate speed regulation. Advanced control algorithms enable efficient motor operation and enhance overall system performance.
In summary, single-phase VFDs provide precise control and regulation of single-phase motors in residential and small-scale applications. With their energy efficiency, motor protection features, harmonic filtering capabilities, and advanced control algorithms, single-phase VFDs enhance motor performance, reduce energy consumption, and ensure reliable operation in various residential and small-scale applications.
Single Phase Vfd,220V Frequency Inverter,Ac Frequency Inverter,High Frequency Inverte
WuXi Spread Electrical Co.,LTD , https://www.vfdspread.com