BT-HSE-65-12 Saite battery quote application




Application area
● UPS/EPS power supply ● Communication equipment ● Power equipment

Product Features
●
Capacity range: 38-250AH
●
Voltage level: 6V, 12V
●
Small self-discharge: ≤2%/month
●
Design Life: Design float life 15 years (25°C)
●
Cycle life: 25% DOD cycles over 1200 times under standard conditions of use
●
Sealed reflect efficiency: ≥98%
●
Shelf Life: After fully charged, it can be left for 2 years at 25°C, and the remaining battery capacity can be over 50%.
After charging, battery capacity can be restored to 100% of rated capacity
●
Anti-deep discharge performance is good: after 100% discharge, charge after four weeks can restore the original capacity
●
Wide operating temperature range: -20 ~ 55 °C
Dimensions


model

Rated voltage (V)

Rated capacity (AH)

Overall size (mm)

reference weight
(kg)

Terminals

long

width

high

Total height

form

BT-HSE-100-6

6

100

195

170

205

210

15.5

F13

BT-HSE-110-6

6

110

281

128

203

206

16.5

F13

BT-HSE-150-6

6

150

260

180

247

252

23.5

F13

BT-HSE-180-6

6

180

298

172

227

232

29.5

F25

BT-HSE-200-6

6

200

323

178

226

256

31.5

F17

BT-HSE-38-12

12

38

196

165

170

170

12.0

F9/F36

BT-HSE-55-12

12

55

229

139

209

228/211

17.3

F12/F25

BT-HSE-65-12

12

65

349

167

174

174

20.0

F11

BT-HSE-70-12

12

70

260

168

212

222/217

21.9

F12/F25

BT-HSE-80-12

12

80

331

173

217

224

26.8

F13

BT-HSE-90-12

12

90

331

173

217

224

27.8

F13

BT-HSE-100-12

12

100

331

173

217

224

30.3

F13

BT-HSE-120-12

12

120

406

173

209

237

35.8

F15/F22

BT-HSE-135-12

12

135

406

173

209

237

38.7

F15/F22

BT-HSE-150-12

12

150

482

171

240

240

45.0

F16/F23

BT-HSE-180-12

12

180

532

207

215

240/218

49.0

F17/F24

BT-HSE-200-12

12

200

523

240

219

245/223

61.6

F17/F24

BT-HSE-250-12

12

250

520

269

220

249/226

74.0

F17/F24

Product consultation (provide quotes, models, product categories, etc.)

Technical Management (Replacement, Inspection Repair, Troubleshooting)

Sales Department 13718954117 (quote marketing, provide product size picture data, etc.)

QQ customer service: 281211862 (quick and convenient online consultation)

Friendly Links GNB Battery
Saite battery

What is the meaning of battery capacity?
The 20-hour discharge rate (C10) typically represents the rated capacity of the battery, that is, discharging at a constant current for 20 hours at 25°C to the termination voltage (1.75V per cell). This current is 20 times the battery capacity. The capacity is generally represented by the AH number. For example, a 12V/100AH ​​battery means that the battery can be discharged at a constant current of 5A (0.05C) to a termination voltage of 10.5V and can be continuously discharged for 20 hours. In addition, it should be noted that the battery discharge time and discharge current is not a linear relationship, such as the 100AH ​​battery discharge with 100A current can not support 1 hour, only tens of minutes; while the current discharge with 1A, it will exceed 100 hours (not recommended this way Discharge).

4000-8000 Kw Diesel Engine

Marine Diesel Engine 4000Kw,Water Cooled Diesel Marine Engine,Marine Diesel Engine 8000Kw,Direct Injection Diesel Engine

Jinan Guohua Green Power Equipment Co.,Ltd. , https://www.guohuagenerator.com