38kv Bil200kv Power Transformer for Recloser Pole Mounted

Model NO.: JDJJ
Usage: Single-phase Transformer, Power Transformer
Frequency Characteristics: High Frequency
Trademark: HEMG
Transport Package: Carton with Wooden
Specification: 15KV/27KV/38KV, 50HZ/60HZ,
Origin: China
Model NO.: JDJJ
Usage: Single-phase Transformer, Power Transformer
Frequency Characteristics: High Frequency
Trademark: HEMG
Transport Package: Carton with Wooden
Specification: 15KV/27KV/38KV, 50HZ/60HZ,
Origin: China
38kv Bil200kv Power Transformer for Recloser Pole Mounted
8.02.MANUFACTURER
′S GUARANTEED TECHNICAL DATE SCHEDULE
FOR 33kv OUTDOOR TYPE SINGLE PHASE POTENTIAL TRANSFORME
             
             
S1.No. Description Unit BPDB′S Requirement Manufacturer′s Guaranteed Particulars
1 Manufacturer′s name&country   To be mentioned HEMG
2 Manufacturer′s model no.   To be mentioned JDJJ-33KV
3 Type   Induction type Induction type
4 Construction   Oil Tank Oil Tank
5 Sealed Oil Tank YES/NO To be mentioned YES
6 Ratio V (33000/√3)/(110/√3)/(110/3) (33000/√3)/(110/√3)/(110/3)
7 No of phase Nos single phase single phase
8 Total capacitance at 100Hz PF To be mentioned 28
9 50HZ1(one)minute withstand voltage wet KV To be mentioned 68
10 Impulse withstand (1.2/50 micro sec wave) KV 170 170
11 Rated burden per phase VA (20+20) 20+20
12 Class of Accuracy:-      
  a)Metering   0.2 0.2
  b)Protection   3P 3P
13 Temperature co-efficient of ratio per ºC   To be mentioned YES
14 System Earthing   Effectively earthed Effectively earthed
15 Creepage Distance mm/kv 25(Min) 25(Min)
16 Maximum errors with 5%primary voltage :      
  a)RatiO % To be mentioned + - 0.2%
  b)Phase angle minutes To be mentioned 10
17 Total weight complete KG    
18 Outling Dimensional&Cross-section Drawings of offered CT&Mounting structure    To be submitted 80x46x105CM -yes
19 Printed catalogue describing specification and technical data of the offered type CT    To be submitted yes
20 Standard     As per relevant IEC60044-2 Standard yes
             
38kv Bil200kv Power Transformer for Recloser Pole Mounted
8.02.MANUFACTURER
′S GUARANTEED TECHNICAL DATE SCHEDULE
FOR 33kv OUTDOOR TYPE SINGLE PHASE POTENTIAL TRANSFORME
             
             
S1.No. Description Unit BPDB′S Requirement Manufacturer′s Guaranteed Particulars
1 Manufacturer′s name&country   To be mentioned HEMG
2 Manufacturer′s model no.   To be mentioned JDJJ-33KV
3 Type   Induction type Induction type
4 Construction   Oil Tank Oil Tank
5 Sealed Oil Tank YES/NO To be mentioned YES
6 Ratio V (33000/√3)/(110/√3)/(110/3) (33000/√3)/(110/√3)/(110/3)
7 No of phase Nos single phase single phase
8 Total capacitance at 100Hz PF To be mentioned 28
9 50HZ1(one)minute withstand voltage wet KV To be mentioned 68
10 Impulse withstand (1.2/50 micro sec wave) KV 170 170
11 Rated burden per phase VA (20+20) 20+20
12 Class of Accuracy:-      
  a)Metering   0.2 0.2
  b)Protection   3P 3P
13 Temperature co-efficient of ratio per ºC   To be mentioned YES
14 System Earthing   Effectively earthed Effectively earthed
15 Creepage Distance mm/kv 25(Min) 25(Min)
16 Maximum errors with 5%primary voltage :      
  a)RatiO % To be mentioned + - 0.2%
  b)Phase angle minutes To be mentioned 10
17 Total weight complete KG    
18 Outling Dimensional&Cross-section Drawings of offered CT&Mounting structure    To be submitted 80x46x105CM -yes
19 Printed catalogue describing specification and technical data of the offered type CT    To be submitted yes
20 Standard     As per relevant IEC60044-2 Standard yes
             