- Model NO.: LS-T13
- Conductor Circuit: Multi Circuit
- Materials: Steel
- Style: Independence Tower
- Name: Monopoles Camouflage Tree Telecommunication Towers
- Avaivable Height: 5-100m
- Voltage: 10kv 35kv 110kv 220kv 500kv 750kv
- Antenna Support Quantity: 3-18 PCS
- Payment Way: 30% Down Payment
- Trademark: LU STAR
- Specification: Telecom tower
- HS Code: 73082000
- Usage: Flying Angle Tower, Crossing Tower, Tension Tower, Angle Tower, Terminal Tower, Transposition Tower, Branching Tower
- Certification: ISO, GS
- Standard: Standard
- Structure: Y Type
- Material: Q235 Q345 Q390 Q420 Gr65
- Galvanized: Hot DIP Galvanization
- Wind Pressure: 5-180 Km/H
- Design Free: Yes
- Lifespan: 50 Years
- Transport Package: by Sea or Land
- Origin: China
Monopoles Artificial Pine Camouflage Tree Telecommunication Towers
Specification:
Height | 6-50M |
Wind Pressure | 5-180 KM/H |
Maximum Design Wind Speed | 330km/h |
Material | Q345/Q235 |
Appearance | Hot dip galvanization and color paint as customer's request |
Lifetime | 30Â years |
Antenna Support Quantity | 3-18 PCS |
Microwave Dish Quantity | 3-10 PCS |
Spare Parts | All necessary parts for installation and connection |
Foundation type | Independent foundation/Raft ffoundation/Pile foundation |
Type | Single pole |
Suitable Places | Hotel, park, business street, square, station and exclusive residential district, etc |
Standards
Bespoke Telecom tower could be fabricated as per GB, EN or ASTM standard with high quality.
Quality control
100% inspection: Each member will be checked by our QC team to ensure all members are qualified before delivery.
Packaging
Set-wisely packing or member-wisely packing as per client's requirements.
Tower members: One steel tower is separated into several bundles.
Bolts: Packing material is robust nylon bag or steel drum
Experiences
Our products have been exported to Philippines, India, Indonesia, Russia, Nigeria, South Africa, UAE and Bahrain etc for 40 countries.
Power Transmission Line Tower
Communication Tower
Substation Steel Structure
Flare Tower
LSAW Steel Pipe

Our Project
>>.Ethiopian 400kv substation
>>.Macao University of Science&Technolofy Stadium
>>.The China Petroleum University Gymnasium
>>.Wuhan Qiantai Theater
>>.The Stadium Of Zibo City
>>.Huizhou Stadium

Quality Test:
Before put into production, all the material must pass the chemical and physical analysis to make sure that they have met the requested strength and component. we have more than 15 inspection procedures from incoming raw material to finished products.
Before shipment, we have a final inspector manager to check the products on every detail and component to make sure it all meet the drawing.

Company Advantage:
1. The company has advanced digital physical and chemical laboratory.  Â
2. We have one 3000 tons CNC bending machine, have two domestic advanced digital automatic production line for steel pipe tower, have 6 automatic numerical control robot welding system, havetwo Steel tube joint welding machine , have 4 CNC plasma flame cutting machine, have 6 High
speed CNC Angle steel line and steel plate production line, one CNC tower foot welding robot system. ,2 CNC Plane drilling machine,1 sand shot blasting machine, 1 gantry type submerged arc
welding machine.6 cutting/shearing machine Â
3. Annual production capacity of 200, 00 tons of hot galvanizing line and one Automatic  centrifugal bolt galvanizing line.Â


Delivery Period :
(1) Less than 100ton: Within 1 Months after receiving the advance payment.Â
(2) 100ton ~ 300ton: Within 2 Months after receiving the advance payment.Â
(3) 300ton ~ 600ton: Within 3 Months after receiving the advance payment.Â
(4) 600ton ~ 1500ton: Within 4 Months after receiving the advance payment.Â
Why Choose us?Â
* Tower Design tailor made to your requirementsÂ
* Pre Dispatch inspection by buyer or international inspection agency.Â
* Steel certified as per international.Â
* Design of Tower as per China/ International design standards.Â
* Galvanization as per international standard.Â
* Timely project completion.Â
* Convenient transportation to Qingdao port & airport(only one hour)
* We are manufacturer. We have our own land & factory. The land was bought instead of rent.
* Independent import & export authorization from government.
* Price is competitive
Â
XLPE Insulated Electrical Cable For Rated Voltage 3.6/6KV~26/35KV
For XLPE insulated power cable, either chemical method or physical method is employed to transform the molecular structure of PE from chain into three-dimensional network, i.e. thermoplastic PE is transformed into thermo setting XLPE. After cross-linking, the thermal and mechanical properties of PE have been greatly improved while its excellent electrical property are still retained.
The maximum permissible operating temperature of the conductor of a XLPE insulated power cable is 90℃ which resistance is higher than that of PVC or PE insulated power cable. The cable has the advantage of simplicity in construction, lightness in weight, convenience in application besides its excellent electrical, thermal, mechanical and anti-chemical corrosion properties. It can also be laid with no limitation of level difference along the route.
1. Product standard
The product is manufactured according to the standard of IEC60502-2 [Extruded solid dielectric power cables for rated voltages from l KV (Um=1.2KV) to 35KV (Um=40.5KV)", BS, DIN and ICEA upon request.Include 33kv Cable,20kv Cable,15kv Cable, 11kv Cable , all of them are manufactured according to the standard.
2. Applications
The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6KV/6KV~26/35KV.
3. Operating characteristics
Rated power-frequency voltage U0/U: 3.6/6KV~26/35KV.
Max. Permissible continuous operating temperature or conductor:90℃.
Max. short-circuit temperature of conductor shall not exceed 250℃. (5s maximum duration)
The ambient temperature under installation should not below 0℃.
The bending radius of a single-core cable should not less than 20 times of the cable diameter.
The bending radius of a three-core cable should not less than 15 times of the cable diameter.
4. Voltage designation
The rated voltage of the cable for a given application shall be suitable for the operating conditions in the system in which the cable is used, and is expressed in the form of U0/U (Um) KV. Where:
U0-The rated power-frequency voltage between conductor and earth or metallic screen, for which the cable designed;
U-The rated power-frequency voltage between conductors, for which the cable designed;
Um-The maximum value of the [highest system voltage" for which the equipment may be used.
5. The values of U0 recommended for cables to be used in three-phase systems are listed below.
System category A-This category comprises those systems in which any phase conductor that comes in contact with earth or an earth conductor, is disconnected from the system within 1 min.
System category B-This category comprises those system which under fault conditions, are operated for a short time with one phase earthed. This period should not exceed 1h. For a longer period, not exceeding 8h on any occasion, can be tolerated. The total duration of earth faults in any year should not exceed 125h.
System category C-This category comprises all systems which do not fall into categories A and B.
6. Construction of cable
3.6/6kV~26/35kV, Single-core, XLPE insulated, power cable
3.6/6kV~26/35kV, Single-core, XLPE insulated, steel tape armored power cable
3.6/6kV~26/35kV, Single-core, XLPE insulated, steel wire armored power cable
3.6/6kV~26/35kV, Three-core, XLPE insulated, power cable
3.6/6kV~26/35kV, Three-core, XLPE insulated, steel tape armored power cable
3.6/6kV~26/35kV, Three-core, XLPE insulated, steel wire armored power cable
Single Core Aluminium Conductor,Three Core Copper Conductor,Three Core Aluminium Conductor,33kv Cable,20kv Cable,15kv Cable,11kv Cable,69kv Cable
Huayuan Gaoke Cable Co.,Ltd. , http://www.bjhygkcable.com